BIFoR site of Mill Haft, Staffordshire, UK. Temperature from Fiber Optics Distributed Temperature Sensor (DTS). Soil moisture from Active DTS technique and from FDR point probes (NERC grant NE/P003486/1)
2018-05-15
creation
http://data.bgs.ac.uk/id/dataHolding/13607340
The data comprise of temperatures (degC) from a fibre optic distributed temperature sensor and soil moisture in the form of volumetric water content (VWC), expressed in m3/m3. The measurements were performed in a vegetated hillslope in Staffordshire, UK, in the context of the NERC funded project DiHPS: A Distributed Heat Pulse Sensor Network for subsurface heat and water fluxes. The site was equipped with: 15xVWC point probes (5TM, Decagon Devices) installed at 5 locations along the hillslope. At each location, 3x5TM probes were inserted in the soil at depths of 0.10m, 0.25m, 0.40m from the soil surface 1,512m of fibre optic cable for Active DTS measurements. The fibre was buried in the soil in three overlapped loops of 504m each at 0.10m, 0.25m, 0.40m. The measurements from the 5TM were used to infer a site specific empirical relation to obtain soil moisture from Active-DTS measurements, following the approach from Sayde et al., WRR, 2010 (https://www.researchgate.net/publication/241060722_Feasibility_of_soil_moisture_monitoring_with_heated_fiber_optics)
Professor Stefan Krause
University of Birmingham
School of Geography, Earth and Environmental Sciences
Birmingham
B15 2TT
not available
principalInvestigator
Francesco Ciocca
Silixa Ltd
Silixa House, 230 Centennial Park,
Elstree
WD6 3SN
not available
pointOfContact
notApplicable
https://resources.bgs.ac.uk/images/geonetworkThumbs/6f8869de-bac6-40c9-e054-002128a47908.png
Geology
GEMET - INSPIRE themes, version 1.0
2008-06-01
publication
Soil properties
Soil water
NGDC Deposited Data
Water content
Optical fibres
BGS Thesaurus of Geosciences
2022
revision
NGDC Deposited Data
dataCentre
NERC_DDC
otherRestrictions
no limitations
The dataset is made freely available for access, e.g. via the Internet. Either no third party data / information is contained in the dataset or BGS has secured written permission from the owner(s) of any third party data / information contained in the dataset to make the dataset freely accessible.
otherRestrictions
The copyright of materials derived from the British Geological Survey's work is vested in the Natural Environment Research Council [NERC]. No part of this work may be reproduced or transmitted in any form or by any means, or stored in a retrieval system of any nature, without the prior permission of the copyright holder, via the BGS Intellectual Property Rights Manager. Use by customers of information provided by the BGS, is at the customer's own risk. In view of the disparate sources of information at BGS's disposal, including such material donated to BGS, that BGS accepts in good faith as being accurate, the Natural Environment Research Council (NERC) gives no warranty, expressed or implied, as to the quality or accuracy of the information supplied, or to the information's suitability for any use. NERC/BGS accepts no liability whatever in respect of loss, damage, injury or other occurence however caused.
Available under the Open Government Licence subject to the following acknowledgement accompanying the reproduced NERC materials "Contains NERC materials ©NERC [year]"
English
geoscientificInformation
-2.3100
-2.3000
52.7900
52.8000
2016-11-20
2017-10-09
MS Excel
http://www.bgs.ac.uk/services/ngdc/accessions/index.html#item110870
download
dataset
dataset
INSPIRE Implementing rules laying down technical arrangements for the interoperability and harmonisation of Geology
2011
publication
See the referenced specification
false
Commission Regulation (EU) No 1089/2010 of 23 November 2010 implementing Directive 2007/2/EC of the European Parliament and of the Council as regards interoperability of spatial data sets and services
2010-12-08
publication
See http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:L:2010:323:0011:0102:EN:PDF
false
Soil temperature (DTS): DTS continuously measuring every 30s and 0.25m spatial sampling over the entire 1,512m of buried fibre optic cable. VWC (A-DTS): A-DTS tests were performed by heating in sequence the cable at 0.40m for 930s, then the cable at 0.25m and finally at 0.10m. Applied power rate was 5W/m. Each A-DTS test was automatically repeated 4 times per day (starting at 02:00, 08:00, 14:00, 20:00). DTS temperatures during each of the heating cycles were time-integrated to produce cumulative temperature values at each 0.25m spatial sample along the fibre optic Cumulative temperatures were converted into VWC by means of a site specific empirical relationship carried out during the first A-DTS tests performed in 2015-2016. A detailed description of the installation, DTS data, and calibration of the system is contained in Ciocca et. al, 2018 (in preparation)