Fluorimeter response of ruthenium based sensor to mercury ions in water and acetonitrile
Default
Identification info
- Metadata Language
- English (en)
- Character set
- utf8
- Dataset Reference Date ()
- 2022-02-16
- Identifier
- doi: / 10.5285/bc82f15b-8db6-4398-bfec-655a1eecf2d7
- Other citation details
- Fairbanks, S., Thomson, J., Martin, N. (2022). Fluorimeter response of ruthenium based sensor to mercury ions in water and acetonitrile. NERC EDS Environmental Information Data Centre 10.5285/bc82f15b-8db6-4398-bfec-655a1eecf2d7
- GEMET - INSPIRE themes, version 1.0 ()
-
- Human Health and Safety
- GEMET - Concepts, version 4.1.3
- Keywords
-
- Hg
- dental amalgam
- Limitations on Public Access
- otherRestrictions
- Other constraints
- no limitations
- Use constraints
- otherRestrictions
- Use constraints
- otherRestrictions
- Other constraints
- If you reuse this data, you should cite: Fairbanks, S., Thomson, J., Martin, N. (2022). Fluorimeter response of ruthenium based sensor to mercury ions in water and acetonitrile. NERC EDS Environmental Information Data Centre https://doi.org/10.5285/bc82f15b-8db6-4398-bfec-655a1eecf2d7
- Topic category
-
- Health
Distribution Information
- Data format
-
-
Comma-separated values (CSV)
()
-
Comma-separated values (CSV)
()
- Resource Locator
-
Download the data
Download a copy of this data
- Resource Locator
-
Supporting information
Supporting information available to assist in re-use of this dataset
- Resource Locator
-
Download the data
Download a copy of this data
- Resource Locator
-
Supporting information
Supporting information available to assist in re-use of this dataset
- Quality Scope
- nonGeographicDataset
- Other
- nonGeographicDataset
Report
- Dataset Reference Date ()
- 2010-12-08
- Statement
- Calibration is done by measuring the luminescent response of the sensor (exciting at 500nm) to various concentrations of Hg(II). A linear relation to increasing mercury concentration can be applied to measure unknown sample concentrations. The calibration graphs from each of the raw fluorimeter data are given in the PowerPoint file. The file showing the dental clinical and amalgam samples are tested using a 1µM sensor to see whether a measurable response is seen to real mercury samples in different media (saliva, distilled water or amalgam separator supernatant).
Metadata
- File identifier
- bc82f15b-8db6-4398-bfec-655a1eecf2d7 XML
- Metadata Language
- English (en)
- Character set
- ISO/IEC 8859-1 (also known as Latin 1)
- Resource type
- nonGeographicDataset
- Hierarchy level name
- nonGeographicDataset
- Metadata Date
- 2024-01-11T09:35:55
- Metadata standard name
- UK GEMINI
- Metadata standard version
- 2.3